IEC 61980-1 | TEST PORT | TEST METHOD | INTERNATIONAL STANDARD | Test Value RF Level | CANADA STANDARD |
Immunity Requirements Performance
criteria are described in IEC 61000-6-1 and IEC 61000-6-2 |
Table 8 – WPT equipment immunity requirement –
Environment other than residential |
15.1 | WPT system | Electrostatic
Discharge (ESD) | IEC
61000-4-2 (2008) | 8kV/4kV Air/Contact | CAN/CSA-IEC
61000-4-2:12 |
Radiated RF
Fields (80-1000MHz) | IEC
61000-4-3 (2002) | 10 V/m | CAN/CSA-CEI/IEC
61000-4-3-07 (R2011) |
Radiated RF
Fields (1.4-2GHz) | IEC
61000-4-3 | 3 V/m | CAN/CSA-CEI/IEC
61000-4-3-07 (R2011) |
Radiated RF
Fields (2- 2.7GHz) | IEC
61000-4-3 | 3 V/m | CAN/CSA-CEI/IEC
61000-4-3-07 (R2011) |
Magnetic
Fields | IEC
61000-4-8 | 100 A/m | CAN/CSA-IEC
61000-4-8:12 |
AC Power input port (and I/O signal/control connected directly to mains
supply) | Electrical
Fast Transients/Bursts | IEC
61000-4-4 | 2kV (5/50ns, 100kHz) | CAN/CSA-CEI/IEC
61000-4-4-06 (R2011) |
Voltage
Surges | IEC
61000-4-5 | 2 KV
line-to-line 4 KV
line-to-earth | CAN/CSA-IEC
61000-4-5-08 (R2013) |
Conducted RF
Fields (0.15-80MHz) | IEC
61000-4-6 | 10 V (rms) | CAN/CSA-C61000-4-6-09
(R2014) |
Voltage dips
and interruptions | IEC
61000-4-11 (<16A) IEC61000-4-34 (>16A) | 30 % reduction for 25 cycles 60 % reduction for 10 cycles >95 % reduction for 1 cycle 100% reduction for 250 cycles | CAN/CSA-CEI/IEC
61000-4-11-05 (R2014) CAN/CSA-CEI/IEC
61000-4-34-06 (R2011) |
Table 9 – WPT equipment immunity requirement –
residential environment |
15.1 | WPT system | Electrostatic
Discharge (ESD) | IEC
61000-4-2 | 8kV/4kV Air/Contact | CAN/CSA-IEC
61000-4-2:12 |
Radiated RF
Fields (80-1000MHz) | IEC
61000-4-3 | 10 V/m | CAN/CSA-CEI/IEC
61000-4-3-07 (R2011) |
Radiated RF
Fields (1.4-2GHz) | IEC
61000-4-3 | 3 V/m | CAN/CSA-CEI/IEC
61000-4-3-07 (R2011) |
Radiated RF
Fields (2- 2.7GHz) | IEC
61000-4-3 | 3 V/m | CAN/CSA-CEI/IEC
61000-4-3-07 (R2011) |
Magnetic
Fields | IEC
61000-4-8 | 30 A/m | CAN/CSA-IEC
61000-4-8:12 |
AC Power input port (and I/O signal/control connected directly to mains
supply) | Electrical
Fast Transients/Bursts | IEC
61000-4-4 | 1kV (5/50ns, 100kHz) | CAN/CSA-CEI/IEC
61000-4-4-06 (R2011) |
Voltage
Surges | IEC
61000-4-5 | 2 KV
line-to-line 1 KV
line-to-earth | CAN/CSA-IEC
61000-4-5-08 (R2013) |
Conducted RF
Fields (0.15-80MHz) | IEC
61000-4-6 | 3 V (rms) | CAN/CSA-C61000-4-6-09
(R2014) |
Voltage dips
and interruptions | IEC
61000-4-11 (<16A) IEC61000-4-34 (>16A) | 30 % reduction for 25 cycles 60 % reduction for 10 cycles >95 % reduction for 1 cycle 100% reduction for 250 cycles | CAN/CSA-CEI/IEC
61000-4-11-05 (R2014) CAN/CSA-CEI/IEC
61000-4-34-06 (R2011) |
Disturbance Requirement |
Load conditions |
15.2.1.1 | WPT system | Harmonic
emission test | IEC61000-3-2 IEC61000-3-12 | The test load shall enable the WPT system to operate
between 20 % and 80 % of the rated power | |
flicker
test | IEC61000-3-3 IEC61000-3-11 | CAN/CSA-C61000-3-3:14 CAN/CSA-C61000-3-11-06
(R2011) |
Operating conditions |
15.2.1.2 | WPT system | modes of
operation | · standby mode · active mode for
emission · active mode for
immunity | | |
Disturbance limits |
Limits and test conditions for disturbances in the low
frequency (LF) range |
Table 10 – Low frequency disturbances |
15.2.2.2.2 | AC Power | Harmonics | IEC
61000-3-2 (rated current =<
16A/phase) IEC
61000-3-12 (rated current =<
75A/phase) | | |
15.2.2.2.3 | AC Power | Voltage
Fluctuations and Flicker | IEC
61000-3-3 (rated
current =<
16A/phase) IEC
61000-3-11 (rated
current =<
75A/phase) | | CAN/CSA-C61000-3-3:14 CAN/CSA-C61000-3-11-06
(R2011) |
Limits and test conditions for disturbances in the
radio frequency (RF) range |
Table 11 – Radio frequency (RF) disturbances |
15.2.2.3.2 | AC Power | Conducted
disturbances (150kHz-30MHz) | CISPR 11 | CISPR 11
Ed. 5 +am1 Table 6 (Class A) or Table 7 (Class B) | CAN/CSA-CEI/IEC
CISPR 11-04 (R2013) |
15.2.2.3.3 | Telecommunication Lines | Conducted
disturbances (150kHz-30MHz) | CISPR 32 | CISPR 32
Table
A.10 (Class A) or Table
A.11 (Class B) | |
15.2.2.3.4 | WPT system and
enclosure port | Radiated Disturbances (150kHz-30MHz) | CISPR 11 | Table 12 | CAN/CSA-CEI/IEC
CISPR 11-04 (R2013) |
15.2.2.3.5 | WPT system
port | Radiated
disturbances (30MHz-1GHz) | CISPR 11 | CISPR 11 Table 9
(Class A) or Table 11 (Class B) | CAN/CSA-CEI/IEC
CISPR 11-04 (R2013) |
| | | | | |
WPT equipment immunity requirement |
Annex B B.2 | WPT with EV | Radiated RF Field (20–2 000
MHz) | ISO 11451-2 | 30 V/m | |
Radio frequency (RF) disturbances |
Annex B B.3 B.4 | WPT system
with EV | Radiated
disturbances (30MHz -
1GHz) | CISPR 12 | limit of
clause 4 | CAN/CSA-CISPR
12-10 (R2014) |
Protection from electro-magnetic field |
Annex C C.1.3 | WPT system
with EV | EMF
measurement procedure | IEC 61786-1 IEC 61786-2 IEC
62233 | | |
IEC 61786-1: Measurement of DC magnetic, AC magnetic and AC
electric fields from 1 Hz to 100 kHz with regard to exposure of human beings
- Part 1: Requirements for measuring instruments IEC 61786-2: Measurement
of DC magnetic, AC magnetic and AC electric fields from 1 Hz to 100 kHz with
regard to exposure of human beings - Part 2: Basic standard for measurements IEC
62233: Measurement methods for electromagnetic
fields of household appliances and similar apparatus with regard to human
exposure |